For an installation to operate well, the fluxes must sometimes respect uniformity criteria in rate distribution. If this condition is not respected, it can cause interference. Aerodynamic problems can be linked to acoustic problems. IAC SIM ENGINEERING offers the following analysis method:
- Sound pressure level measurements far away from and close to the source
- Aerodynamic measurements (selection of fictitious sections, identification of speed vectors and measurements, analysis and presentation of measurements in tables and 3D graphs)
- Aerodynamic study
- Characterisation of speed profiles
- Corrective action research
- Testing and validation of changes
- Validation after on site implementation
Our testing means:
- Anemometers
- Pitot tubes
- Pressure sensing probes
- Temperature sensing probes
- Test room and manufacturing workshop
- Centrifugal fan benches
|